Loading Station Dock
Lift Start Push Button and light*
When depressed will start the lift chain IF the Lift Start button on the operator's console is depressed simultaneously, and not blocked by the safety system.
If the button is held down for an extended period of time, the lift will stop. Light lit when lift running.
Lift Stop (Push Button)* `
When depressed stops the lift.
Top of the Lift
Emergency Stop (Lock off switch)*
When switched off cuts off power to lift drive motor and lap bars and Sets all brakes.
Transfer Brake
Open Brake (Push Button)*
When depressed opens transfer brake, however key switch 'Transfer Brake' on operators console must be in Manual position.